Visual indication and a notifier if a Win911 data connection is lost.

Allows operator to see if Win911 is actively connected to the alarm source. Aids in diagnosing Win911 issues. A visual notification on the screen would let operator know Win911 has lost ability to actively alarm. Also a notifier via SMS, email, vo...
about 6 years ago in WIN-911 Shipped

Support for Shelving and Suppression from FactoryTalk Alarm & Events

I have had issues with Win911 getting stuck because an alarm was active when an operator used the "suppress" feature in FactoryTalk Alarm & Events. The alarm strategy didn't recognize that the alarm was no longer active and wouldn't stop notif...
over 6 years ago in WIN-911 Shipped

Synchronizing Acknowledgements for OPC with group poke like V7

The OPC DA protocol provides only for the transfer of raw data values rather than the alarm events. As a result, WIN-911 manages its own instances of alarm conditions and alarm acknowledgments (in addition to any alarm instances that may exist in ...
over 6 years ago in WIN-911 Shipped

Easy Alarm Formats for Voice Connections

Easier way to edit/modify the way and order of what the voice annunciates via a phone call.
over 6 years ago in WIN-911 Shipped

Remote Standby/Active capability

Be able to remotely activate or deactivate win911 alarm notifications. If someone forgets to switch win911 to active at the end of the night maybe they can text or call to activate it without being at the machine.
almost 7 years ago in WIN-911 Shipped

Heartbeat for InTouch Edge HMI

I would like a heartbeat for the InTouch Edge HMI data source so I can determine when WIN-911 has stop communicating from my HMI screens.
over 7 years ago in WIN-911 Shipped

Saved Views for WIN-911 Log Viewer

Allow me to filter and sort my Log Viewer and save that view (column options, sort, filters) into a small set of views that I can then select from to switch between them. For example, switch between a view of all alarms and a view of high severity...
about 6 years ago in WIN-911 Shipped

Win911 2021 R2 Log Viewer ability to display Alarm Messages for use by Operators

This would provide operators with a definition of the alarm in Log Viewer
over 4 years ago in WIN-911 Shipped

View Log Viewer Remotely

Ability to view the WIN-911 Log Viewer remotely. For example, on a SCADA client. Many times WIN-911 is installed on the server machine which operators don't have access to.
almost 5 years ago in WIN-911 Shipped

OPC Bit selecting similar to V7

V7 migration users often select bits from alarm packed words. This is not available right now. PLC or SCADA programming is needed which is bothersome.
about 5 years ago in WIN-911 Shipped