OPC Data Access - Export Selected/Filtered Alarms

On a large system like the one we have, it lakes an hour to export OPC DA alarms. It would be much faster if you could export alarms that you select or filter.
over 2 years ago in WIN-911 2

I would like a heartbeat from WIN-911 that I can monitor in FTViewSE.

I need to know that WIN-911 is not working. If I need an alarm annunciated, I need to be sure that WIN-911 is alive. Monitoring a heartbeat would let me know that it is still functioning and can be relied upon, especially after hours.
almost 6 years ago in WIN-911 3 Will not implement

Unzip ProgramData files as part of installation.

See support case #00077325. It would be beneficial if the installation unzips those files, rather than needing one-time file access post-installation in order for the software to work correctly. As soon as I gave myself Full Control of those files...
over 1 year ago in WIN-911 0

Failover utility should check network connectivity between primary and secondary systems. In case of network failure it's better to have both unreachable primary and secondary active than none (It's unclear if primary is still connected to the gateway) .

It seems that the Failover utility is coded to act only when the modules fail and doesn't check if primary is reachable on the network after initial connection. It would be great to have secondary Win911 be activated in case of primary being unrea...
10 months ago in  0

Properly browse OPC tree structure

The OPC DA implementation used by Win911 attempts to pull in every single record field on a particular DA Server as opposed to going branch by branch. On large systems, it is unusable as it is trying to collects millions of record fields.
about 5 years ago in WIN-911 2

Allow Advanced policy loops function blocks to go flat 60 minutes and 1000 loop max

The addition of function blocks and loops would make our outdialer system much more robust, however the 59m, 55s timer max and 99 loop max are insufficient for large systems where there could be 200+ loops before an alarm is cleared (100 loops at ...
almost 2 years ago in WIN-911 0

Bring back text based log files.

Allows management to confirm operators are responding to call outs. Text files that are created daily much easier to deal with then using the log viewer. Log file folder can be shared and viewed across network. If possible add ability to email log...
over 5 years ago in WIN-911 0

Allow Bulk Edit of InTouch Tags for Notification Policies

Allow bulk edit of InTouch tags to change notification policies.
almost 2 years ago in WIN-911 0

Dynamic Level Alarm Limit when using OPC

It would be nice to reference an OPC tag for use as the limit setpoint on level alarms, ie I have a system that has certain times when a wetwell alarm could be modified. It creates added work and the possibility of human error to have to remember ...
11 months ago in WIN-911 0

Provide a method for printing out or exporting the SIA configuration to a csv file.

Would like to be able to print out, or export to csv, the list of items and their alarms, tactics, strategies, contact list, etc.
almost 5 years ago in WIN-911 8