WIN-911

BACnet/IP - Event Enrollment Alarms

Network alarms are broadcasted with Alarm, Acknowledged or Normal conditions, and is the primary data protocol used by Building Automation systems in North America. We used WIN911 for a boiler plant, but we had to use a PLC with OPC-DA since you d...
over 5 years ago in WIN-911 0

List of All Alarms under a specific LABEL?

Seems no easy way to see all alarms/blocks under a specific Lable. We are using Label as replacement of Groups (old version). Groups were used as process areas to group relaetd area alarms. In new version we are using Lables as workaround of Group...
over 5 years ago in WIN-911 1 Already exists

Win911 - please support iFIX ReAlarm feature

ReAlarm definition: The ReAlarm Time will reissue the alarm if the tag is still in an alarm state after the amount of time specified. Or in other words it is the length of time to wait before re-issuing an alarm. Can be configured as any time from...
almost 2 years ago in WIN-911 0

Log Viewer Date Format by Region - bug fix

Date format is wrong in Log Viewer. When the PC Region is set to <dd/mm/yyyy>, the Log Viewer still displays as <mm/dd/yyyy> which is confusing and essentially wrong for this region. 1/7/21 is the 1st of July in this part of the world....
almost 6 years ago in WIN-911 1

dedicated lock for Ultimate License when screen is closed

It would be nice to have the License Lock based on the License Type and stay until it has been changed. i.e. if Basic "Pro" Perpetual lock on Basic, If Perpetual "Ultimate" Lock it on "Ultimate " until changed.
almost 2 years ago in WIN-911 0

Win-911 mobile notification format editing

We would like the ability to control the format of the mobile pop-up notification. The current format is confusing for most of our users and does not provide easily actionable information without a significant amount of context.
almost 4 years ago in WIN-911 3

A Report feature to see alarms from the past 6 or 12 hours.

This was a request from a plant's management staff. A report feature to see alarms that became active during the last 6 or 12 hours would be useful for summarizing what occurred at the plant during a single shift or day. The report could be seen o...
about 6 years ago in WIN-911 1 Already exists

number of Repeat times for alarms broadcast in Local announcer

Recommend to have setup for number of Repeat times for alarms broadcast in Local announcer.
about 6 years ago in WIN-911 0

Tray Icon to to Show Interactive status

Tray Icon to show that the Win 911 is running. Allows operator visual confirmation the dialer is active. Added right click functionality to show connector status, bring up log viewer and restart would be helpful.
about 6 years ago in WIN-911 0

Fix FactoryTalk A&E Application Connection After Restart Issue

Give Greater Control to stop,start and connect for FTAE. Factory Talk A&E Application Connection will not allow any Network Application connection to work for the first time after a restart and an engineer must set the Application to a Local F...
about 4 years ago in WIN-911 1