WIN-911

Showing 190 of 190

option to remove the Comment dialog in the mobile app.

The Comment dialog that appears in the app when an alarm is acknowledged is of no use to us and we would like to see the option to not have that display at all. It's an extra step that isn't needed.
over 1 year ago in WIN-911 0

Announcer as a service

We run announcer on our Win-911 server for local announcements. We would like it to run as a service so we don't have to login every time the system is rebooted to restore local announcements. This may also be useful for systems that run elsewhere...
over 1 year ago in WIN-911 1 Will not implement

Text Response that the acknowlagement was accepted

When an operator acknowledges an alarm via text their is no easy way to only notify that one person that their response was accepted without notifying the entire call out list. An imediete response of the new status would be greatlly benneficial i...
almost 3 years ago in WIN-911 0

Notification Alarm Count on WIN-911 App Icon

As did the Mobile-911 App, the WIN-911 Mobile App should display the total number of active alarms. While the alarm banner is provided, it is only useful if the user goes into Phone Settings and changes the setting for the banner from 'Temporary' ...
over 4 years ago in WIN-911 1

Easy Alarm Formats for Voice Connections

Easier way to edit/modify the way and order of what the voice annunciates via a phone call.
over 4 years ago in WIN-911 1 Planned

Expose system status monitor module information via SNMP and/or custom alarms

Make the info in system status monitor module available via SNMP, so it can easily be monitored by IT. Additionally custom alarms that can be send via the notifiers may be usefull
over 1 year ago in WIN-911 0

Multiple Email Formats /color change Based On Tag Severity

It would be nice to have the ability to use different email formats based on the Tag severity. ex. Critical alarms come in as red and win 911 format would be red. A valve transition event with a low severity would come in as yellow or orange, and ...
over 1 year ago in WIN-911 0

WIN-911 Mobile to reflect alarms based on active alarming systems at all times (to mirror SCADA behavior)

We have duplicate WIN-911 Alarms showing in the Mobile App summary due to have redundant WIN-911 App Servers (see screenshot). This is a significant user adoption issue because it causes confusion by having duplicate alarms. This specific example ...
about 3 years ago in WIN-911 1

CIMPLICITY Missing Tag Name

Win-911 Version 4.19.17 tag name present in alarm message Upgraded to Win-911 Version 2021 R6 tag name disappear and no one knows why, certainly not in the release notes. An upgrade caused a critical feature no longer function, great job Win-911 d...
over 1 year ago in WIN-911 0

Ability to select what is displayed as a value in reports, i.e., number of decimal places, True/False, On/Off, Open/Closed.

It would make viewing the reports easier by not having 12 decimal places to the right and would more closely indicate the actual condition of a status point. Currently it only displays True/False. Depending on the programming of the controllers in...
about 3 years ago in WIN-911 0